Home / Testing report 2
Categories

    Testing report 2

    This report describes the Temperature Mapping study of a “123coolbox” shipping container as described under ”section 5, System Description”. The report outlines the study aim, which was to establish through thermal evaluation that the 123coolbox shipping container maintains temperature within the customer’s pre-defined required limits. It provides documented evidence that the performance of the container meets pre-determined acceptance criteria. 
    This was achieved by examining the thermal characteristics of the container over a minimum period of 51 hours. The container was loaded with 10 litre canisters of water, placed inside an environmental chamber and subjected to a multi-temperature profile. Temperature data loggers were positioned inside the unit with data logging frequency set at five minute intervals. The purpose was to ensure that temperature was maintained within the following limits, with no unexplained excursions: 
    123coolbox Shipping Container Operating Limits: Maintain Internal Temperature at 2 to 8°C